SkyView System Installation Guide - Revision R 5-1
5. SV-ADAHRS-200/201 Installation and Configuration
The SkyView ADAHRS module uses MEMS sensor technology to accurately measure inertial,
magnetic, and air data. To ensure accuracy in its readings, it is very important that you install
the module correctly and perform the specified calibration steps. This chapter guides you
through that process.
Dynon sells a primary ADAHRS model (SV-ADAHRS-200) and a backup model (SV-ADAHRS-201).
Throughout the guide, these models are collectively referred to as “SV-ADAHRS-200/201.” The
SV-ADAHRS-200 and SV-ADAHRS-201 are identical in functionality.
Figure 24 is a high-level overview of a suggested and installation and configuration procedure
for the SV-ADAHRS-200/201:
Choose a
location based on
Location
Requirements
Section
Install SkyView
network cabling
Prepare the
location
Install AOA/Pitot
probe
Install static port
(not covered in
this guide)
Install pneumatic
plumbing
Install OAT probe
and wiring
Install ADAHRS
module with
electrical and
pneumatic
connections
Configure
ADAHRS-related
settings on
SkyView display*
Perform magnetic
calibration
Perform AOA
calibration
Reference
Accessory
Installation and
Configuration
Chapter
*Assumes SV-D700 or SV-D1000 is properly installed and working.