Autopilot Servo Installation, Configuration, and Calibration
10-14 SkyView System Installation Guide - Revision R
(Optional) External LEVEL Button
SkyView supports an external button that engages LEVEL mode in the same way that pressing
MAIN MENU > AUTOPILOT > LEVEL and the LEVEL button on the (optional) SV-AP-PANEL. This
allows the pilot to mount a permanent, dedicated button on the panel or yoke/stick.
This button should be a single pole, normally open, momentary button. Verify that the two
terminals of the button are shorted when the button is pressed and open (no-connect) when
the button is released. One terminal of the button should (momentarily) connect the SkyView
display 37-pin connector Pin 28 (Contact #1 Input), and the other terminal of the button should
connect to Ground.
During bootup, SkyView checks the status of the External LEVEL Button. If SkyView detects that
the button is pressed (the input is grounded) during bootup, the External LEVEL Button is
assumed to be stuck (or incorrectly installed), resulting in:
1. A message is displayed: EXT LEVEL BUTTON STUCK, and
2. The External LEVEL Button input is ignored for the remainder of the time SkyView is
operational (will be checked again at next bootup).