SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-61
The alarm type for oil temperature is the “self-clearing” type.
EMS Sensor Definitions, Mapping, and Settings
EMS Sensor Definitions
All EMS sensor installations require a SkyView Sensor Definitions file. This file provides
characterizations of all sensors that SkyView supports, and is occasionally updated to add
additional supported sensors and correct issues with existing sensors. The most current version
of the SkyView Sensor Definitions file is preloaded onto each display prior to shipment. The
most current version of the SkyView Sensor Definitions file can be downloaded from
http://downloads.dynonavionics.com.
If you have more than one SkyView display, and the SkyView Sensor Definitions file on each
display is different from one another, a warning message will be displayed:
EMS SFG FILE MISMATCH.
If you need to update the SkyView Sensor Definitions file, download the file and use the
instructions found in the How to Load and Delete Files Section.
EMS Sensor Input Mapping
If your engine installation is listed in the Example Engine Sensor and Transducer Installations
Section, we recommend you install one of the sensor mapping and settings files onto the
SkyView display using the instruction found the How to Load and Delete Files Section. Then
update or modify the sensor map and settings based on your installation.