SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-9
Rotax 912
Harness
(except 912 iS)
(100399-004)
4-cyl Harness
(100399-001)
6-cyl Harness
(100399-002)
Table 15–SV-EMS-220/221 Female D25 Pin-to-Sensor Compatibility
The Rotax harness only has EGTs 1 and 2 wired, as the EMS measures the Rotax-supplied
resistive CHTs through its GP inputs. The four-cylinder harness only has EGTs 1 through 4 and
CHTs 1 through 4 wired. On the supplied harness, each pair of wires is encased in brown
insulation and labeled with corresponding cylinder number. Inside the outer insulations, each
wire in the pair has the color listed in Table 15 and Figure 29.
If you make a custom thermocouple harness, note that all differential
thermocouple inputs on the D25 and the D37 (SV-EMS-220 only) connectors are
compatible with both J and K type thermocouples. Note that you will need to
configure SkyView to support any installations that are not already supported in
the preconfigured downloadable resources.