SV-AP-PANEL Installation
SkyView System Installation Guide - Revision R 18-5
Aircraft Electrical Ground
If trim motor(s) control is not used, do not connect. Power
and ground for the SV-AP-PANEL front panel buttons is
provided by SkyView Network.
Motor 1: Pin 7 polarity is +, Pin 8 polarity is -
Motor 1: Pin 7 polarity is -, Pin 8 polarity is +
Motor 1: Pin 7 polarity is +, Pin 8 polarity is -
Motor 1: Pin 7 polarity is -, Pin 8 polarity is +
Pin 3 or Pin 5 grounded:
Pin 7 polarity is +, Pin 8 polarity is -
(Motor rotates in one direction)
Pin 4 or Pin 6 grounded:
Pin 7 polarity is -, Pin 8 polarity is +
(Motor rotates in the other direction)
If trim motor(s) control is not used, do not connect. Power
and ground for SV-AP-PANEL front panel buttons is
provided by SkyView Network.
Motor 2: Pin 14 polarity is +, Pin 15 polarity is -
Motor 2: Pin 14 polarity is -, Pin 15 polarity is +
Motor 2: Pin 14 polarity is +, Pin 15 polarity is -
Motor 2: Pin 14 polarity is -, Pin 15 polarity is +
Pin 10 or Pin 12 grounded
Pin 14 polarity is +, Pin 15 polarity is -
(Motor rotates in one direction)
Pin 11 or Pin 13 grounded
Pin 14 polarity is -, Pin 15 polarity is +
(Motor rotates in the other direction)
Table 62 - SV-AP-PANEL Trim Motor Control Pinout