VAL Avionics NAV 2000 Guía de instalación Pagina 320

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 401
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 319
SV-COM-X83 Installation, Configuration, and Testing
17-14 SkyView System Installation Guide - Revision R
On the SV-COM-T8 #1 end, continue the shield as far into the connector as possible
until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-T8 #1
end of this cable is not electrically connected at SV-COM-T8 #1.
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between SV-COM-T8 #1 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and 25:
This cable consists of two wires plus shield.
Use one of the wires to connect SV-COM-T8 #1 Pin 23 to SV-INTERCOM-2S Pin 25.
Use the other wire to connect SV-COM-T8 #1 Pin 9 to SV-INTERCOM-2S Pin 1 (see
instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the SV-COM-T8 #1 end, continue the shield as far into the connector as possible
until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-T8 end
of this cable is not electrically connected at SV-COM-T8 #1.
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between SV-COM-T8 #2 Pins 1 and 2, and SV-INTERCOM-2S Pins 1 and 7:
This cable consists of two wires plus shield.
Use one of the wires to connect SV-COM-T8 #2 Pin 2 to SV-INTERCOM-2S Pin 7.
Use the other wire to connect SV-COM-T8 #2 Pin 1 to SV-INTERCOM-2S Pin 1 (see
instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the SV-COM-T8 #2 end, continue the shield as far into the connector as possible
until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-T8 #2
end of this cable is not electrically connected at SV-COM-T8 #2.
On the SV-INTERCOM-2S end, prep the shield into a "pigtail" so that you can solder to it
(see instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
Shielded cable between SV-COM-T8 #2 Pins 23 and 9, and SV-INTERCOM-2S Pins 1 and 15:
This cable consists of two wires plus shield.
Use one of the wires to connect SV-COM-T8 #2 Pin 23 to SV-INTERCOM-2S Pin 15.
Use the other wire to connect SV-COM-T8 #2 Pin 9 to SV-INTERCOM-2S Pin 1 (see
instructions below - Terminating Shielded Cables to Pin 1 of SV-INTERCOM-2S).
On the SV-COM-T8 #2 end, continue the shield as far into the connector as possible
until you're forced to pare it back to access the two inner wires. Put some heat shrink
tubing over the shield to keep it electrically isolated - the shield at the SV-COM-T8 end
of this cable is not electrically connected at SV-COM-T8 #2.
Vista de pagina 319
1 2 ... 315 316 317 318 319 320 321 322 323 324 325 ... 400 401

Comentarios a estos manuales

Sin comentarios