SkyView System Installation Guide - Revision R 24-1
24. Appendix E: Serial Data Output
Any of SkyView’s five RS232 serial ports can be configured to output various types of serial data
via SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP. Technical information on the
installation and connection to the serial ports can be found in the Serial Devices section of the
SkyView Installation Guide. To output serial data, you must select either DYNON EMS, DYNON
ADAHRS, DYNON SYSTEM, DYNON ADAHRS + SYSTEM, DYNON ADAHRS + EMS, or DYNON
ADAHRS + SYS + EMS, NMEA OUT (BASIC), or NMEA OUT (FULL) as a Serial Out device, select a
baud rate, and connect the serial port to an external serial device such as a PC. The serial data
can be logged using any standard serial terminal program, a data logger program, or dedicated
data logger device. All numbers are output in decimal except where noted and are standard
ASCII. To view the data using a terminal program, that program should be configured to receive
data in the following format:
Baud rate: Set baud rate to match the baud rate selected on SkyView’s serial port
Data: 8 bit
Parity: none
Stop: 1 bit
Flow control: none