SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide - Revision R 7-7
Table 13–Sensor and Transducer Compatibility Level Key
Future firmware updates may expand the scope of the compatibility levels listed in Table 13.
The tables on the following pages specify the sensor and transducer types that are supported
by each pin on the male D37 and female D25 SV-EMS-220/221 connectors and the wire harness
wire colors. Note that the only purpose of the 25-pin SV-EMS-220/221 wire harness is for
thermocouple connections. This guide generally refers to the different variations of this as the
thermocouple harness. Each connector’s table is followed by a pin insertion view (rear)
diagram.
EMS 37-pin
Harness Wire
Color
Voltmeter 1 (0 to 30 volts DC)
Voltmeter 2 (0 to 30 volts DC)
Enhanced General Purpose Input 4
Auxiliary 12 volt DC Output
Auxiliary 5 volt DC Output
Fuel Flow Input 2 (Return)
Enhanced General Purpose Input 2
Enhanced General Purpose Input 3
Manifold Pressure
(100434-000)