SV-EMS-220/221 Installation and Configuration
7-50 SkyView System Installation Guide - Revision R
Capacitance-to-Voltage Converter installation instructions.
Note that SkyView displays are typically preconfigured to use resistive probes. Using capacitive
sensors instead of resistive probes requires that you change EMS settings in a few places. First,
change the pins used for fuel quantity via the SETUP MENU > EMS SETUP > PIN SENSOR INPUT
MAPPING… menu. Then, delete the default fuel quantity widgets from each screen layout
under SETUP MENU > EMS SETUP > SCREEN LAYOUT EDITOR. Finally, add the new fuel quantity
widget(s) that will be available for the capacitive probes.
Ammeter Shunt
The ammeter shunt should be mounted so that the
metal part of the shunt cannot touch any part of the
aircraft. The ammeter shunt can be installed in your
electrical system in one of three locations as shown in
Figure 42.
If you have a Vertical Power VP-X system in your
aircraft, use either position A or position B. Position C is not useful in a VP-X installation
because the VP-X measures aircraft loads directly.
Position AAmmeter indicates current flow into or
out of your battery. In this position, it will show
both positive and negative currents (i.e., -60 amps
to +60 amps).
Position BAmmeter indicates only the positive
currents flowing from the alternator to both the
battery and aircraft loads. (0A-60A)
Position CAmmeter indicates the current flowing only into the aircraft loads. (0A-60A)
Pin
Color
Function
24
Orange/green
amps high
25
Orange/purple
amps low
Table 37Amps Pins
Figure 41Amps Shunt